Log On
Clear
Permits
By Address
By Permit Number
Fee Calculator
Plans
By Address
List of Plans
Links
City PlanTrac
Colorado Springs Utilities
Home
Please wait...
Contact Support
Plan
453 STRONG CT, CRIPPLE CREEK, CO 80813
PERMIT#: A47453
County Parcel #: 1387.233010290
Roof Truss P/SF: ?
PROJECT: DETACHED GARAGE (
436
)
Submit Date
Approval Date
Type of Plan: Normal
Review Type: Parallel
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
County Map & Data
PPRBD Directions
Path 1 Location
Path 2 Location
Details
View
Log
Time Summary
Required Departments: 4
Log Entries: 8
Department
S
BoundColumn_2
Department
Construction
A
C
Construction
Floodplain
A
W
Floodplain
Roads & Bridges
A
R
Roads & Bridges
County Zoning
A
Z
County Zoning
Department
Splice
S
Date
Inspector
Reviewer
Comment
username
Department
tid
Open Plan Room
Original
/
11/4/2014
SHARONOVAO
SHARONOVAO
Path 2 Location = Open Plan Room by SHARONOVAO
Open Plan Room
9295
Open Plan Room
Original
/
11/4/2014
SHARONOVAO
SHARONOVAO
Path 1 Location = Open Plan Room by SHARONOVAO
Open Plan Room
9294
Construction
Original
A
11/4/2014
SHARONOVAO
SHARONOVAO
Construction
9293
Construction
Original
/
10/30/2014
SHARONOVAO
SHARONOVAO
Path 2 Location = Construction by SHARONOVAO
Construction
9275
Construction
Original
D
10/30/2014
SHARONOVAO
SHARONOVAO
PLEASE PROVIDE TWO COPIES OF THE FOLLOWING TO COMPLETE THE PLAN REVIEW PROCESS. A WRITTEN RESPONSE FOR EACH ITEM LISTED BELOW IS REQUIRED THAT SPECIFICALLY IDENTIFIES THE REVISION OR CORRECTION BEING MADE. BUBBLE OR HIGHLIGHT ALL REVISED DETAILS AND DRAWINGS ON NEWLY SUBMITTED PLAN SHEETS.
IF THESE CORRECTION ITEMS ARE ON STAMPED PAGES THEY WILL REQUIRE THE DESIGN PROFESSIONAL OF THAT DISCIPLINE TO PROVIDE AND STAMP THESE NEW PAGES OF CORRECTIONS.
Please provide a letter addressing the fowling corrections:
? 1. Submitted architectural plans are not printed to scale, please provide.
? 2. Provide Truss layout.
? 3. H5 clips are not sufficient for the uplift of the truss, please provide mechanical connections per individual truss uplifts.
? 4. Foundation engineer has no reference to the soils report on his plans and psf of the designed foundation was not identified, please have engineer address through plans or a letter.
NOTE: The remainder of the review will be completed as soon as the items are addressed.
IF YOU HAVE ANY QUESTIONS, PLEASE CALL ME AT (719) 686-5405, OR EMAIL ME sharonovao@co.teller.co.us, TO DISCUSS THE CONDITIONS OR SET UP AN APPOINTMENT TIME WHEN I CAN BE AVAILABLE TO MEET YOU AT THE COUNTER TO GO OVER THE PLANS.
Olya Sharonova
Plans Examiner, Teller County
Construction
9274
Roads & Bridges
Original
A
10/17/2014
DINNOCENZOM
DINNOCENZOM
Inspected. Approved. Passed. Permit issued. Finaled. Permit in file.
Roads & Bridges
9200
Floodplain
Original
A
10/15/2014
CORCORANC
CORCORANC
FEMA MAP # 08119C0255D
Floodplain
9184
County Zoning
Original
A
10/15/2014
CORCORANC
CORCORANC
County Zoning
9183
© 2024 - PPRBD •