Construction | D | C | Construction | Triage | A | J | Triage | County Zoning | A | Z | County Zoning |
|
| |
|
Construction | Original | D | 8/22/2024 | SNYDERJ | SNYDERJ | Plan Review correction Letter sent 8/20/2024 - JS Additional information required: 1) General Note: No title block on plans. No property address or owner name on plans. 2) Sheet A-6: The deck indicates that a brick knee wall will be built on the outside rim of the deck. Please provide structural plans and stamped details for this assembly. 3) Sheet A-8: No footing, foundation, slab or deck pier details were submitted. Provide engineered footing, foundation, slab and pier details for review with reinforcement requirements (size and grade). Furthermore, the foundation plan indicates a crawlspace, and the cross sections indicate slab on grade. Please address. 4) Sheet A-9: Specify framing members and connections for stairwell openings at all levels. Provide rim construction details for loft at knee wall/guardrail. Provide details for knee wall construction and attachment to loft rim and floor. Complete deck plans including framing, ledger, flashing, beams, posts and mechanical connection details. 5) Sheet A-10: Provide roof joist size, species, grade for the main structure. Glulam beams cannot be used outside unless listed for exterior installation. Please address. 6) Sheet A-12: Please show location of electric service and sub-panels. 7) IECC Compliance: The framing details for your exterior walls don’t support the R-19 value, please provide framing details to demonstrate the R-13 cavity with the R-5 continuous insulation value. The basement wall framing details also do not support the R15 continuous insulation and the R-19 cavity insulation, please clarify. The slab insulation value is only required to be an R-5 not R-35 as submitted, please clarify. | | Construction | 39983 | County Zoning | Original | A | 8/12/2024 | MCBRYDEJ | MCBRYDEJ | The residential single-family permit complies with the setback requirements and is located on a legal lot as per Teller County Land Use Regulations. Furthermore, the property is not situated within or near a floodplain. | | County Zoning | 39839 | County Zoning | Original | / | 8/1/2024 | HOEKMANL | HOEKMANL | TEAMS TO PZ 8/1/2024 | | County Zoning | 39709 | Triage | Original | A | 8/1/2024 | HOEKMANL | HOEKMANL | UNLOCKED PLANS PROVIDED | | Triage | 39708 | Triage | Original | D | 7/31/2024 | HOEKMANL | HOEKMANL | RECEIVED 7/29/2024
DENIED DUE TO PLANS BEING LOCKED
SEPTIC ON PERMIT A51113 - APPROVED FOR 3 BEDROOMS DRIVEWAY ON PERMIT A50204
ARCHERNOELL@GMAIL.COM | | Triage | 39693 |
|
| |
|