| HOMEOWNER | B= | C | 05/04/2012 | cdsd review complete ok to CO | HARRISJ | HARRISJ | | B= | C | 176902 | | HOMEOWNER | BIN | C | 03/22/2012 | RECD RES CHECK | LANDSITTELM | LANDSITTELM | | BIN | C | 176164 | | HOMEOWNER | BIN | P | 06/07/2011 | CEILING OK, ADVISED NEED RES CHECK | LANDSITTELM | LANDSITTELM | | BIN | P | 169781 | | HOMEOWNER | BFR | C | 06/07/2011 | Rec'd eng for I joists | LANDSITTELM | LANDSITTELM | | BFR | C | 169779 | | HOMEOWNER | B16 | C | 05/26/2011 | rcvd floor joist eng to mcl | LOGANS | LOGANS | | B16 | C | 169559 | | HOMEOWNER | BFR | T | 04/21/2011 | PAID (REC#900890) need eng approval for floor I joist, plans call for BCI 450 series, deck ledger needs lag bolts, FOR FINAL STAIR RISERS CANNOT VARY MORE THAN 3/8", OK to insulate areas not needing reinspect. rcvd ltr fro the bci floor joist substitution 05-23-11 sjl for mcl | LANDSITTELM | LANDSITTELM | | BFR | T | 168785 | | HOMEOWNER | BGF | C | 03/22/2011 | | LANDSITTELM | LANDSITTELM | | BGF | C | 168123 | | HOMEOWNER | BUL | C | 08/10/2010 | cmc (Original code: 43, desc: Ice & Water Shield, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BUL | C | 7759 | | HOMEOWNER | BUL | R | 08/04/2010 | --porch roofs are part of eaves and need ice protection-- (Original code: 43, desc: Ice & Water Shield, result: FAIL, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BUL | R | 7993 | | HOMEOWNER | BSH | C | 07/16/2010 | ljm.....roof (Original code: 24, desc: Sheathing, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BSH | C | 8532 | | HOMEOWNER | BSP | C | 06/17/2010 | 11 each (Original code: 21, desc: Deck Piers, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | BSP | C | 9086 | | HOMEOWNER | BSP | C | 06/17/2010 | retaining wall (Original code: 20, desc: Other, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | BSP | C | 9087 | | NORTHSTARR CONSTRUCTION | BFR | C | 06/01/2010 | advised need new framer listed or no inspection....this inspection is to look at log courses....cmc (Original code: 03, desc: Struc Frame, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | BFR | C | 9389 | | HOMEOWNER | BFN | C | 05/24/2010 | ljm (Original code: 02, desc: Struc Foundation, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFN | C | 9555 | | HOMEOWNER | BSP | R | 05/21/2010 | Change Order reviewed and approved...ljm (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 153243 | | HOMEOWNER | BFT | C | 05/19/2010 | LJM (Original code: 01, desc: Footing /Open Hole, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | BFT | C | 9647 | | HOMEOWNER | BFT | R | 05/18/2010 | --need uffer grnd OWNER STATES HE HAS WC FOR WORKERS--cmc (Original code: 01, desc: Footing /Open Hole, result: FAIL, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | R | 9667 | | HOMEOWNER | BSP | R | 05/18/2010 | RCVD OPEN HOLE (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 153282 | | HOMEOWNER | BSP | R | 05/14/2010 | rcvd revised engr design from engr....gave to khd...cmc (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 153266 | | HOMEOWNER | BSP | R | 04/28/2010 | 30 days after final inspection mobile must be removed (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 159190 | | HOMEOWNER | D= | C | 05/07/2012 | | HARRISJ | HARRISJ | | D= | C | 176936 | | INTERMOUNTAIN POWER SERVICES | E= | C | 05/02/2012 | | WILSOND | WILSOND | | E= | C | 176858 | | INTERMOUNTAIN POWER SERVICES | E= | T | 04/13/2012 | PAID (REC#904620) Outside outlet at front of house not on GFI also wired wrong, outlet in upper bedroom wired wrong,stairway to second floor needs a switch in area of stair landing,need connector in brass floor box,need connector in heat controller,dryer wire not fully in box,light in utility room not fastened to box, open box in utility room,under cab lights in kitchen need to wired through a junction box with cover. | WILSOND | WILSOND | | E= | T | 176464 | | INTERMOUNTAIN POWER SERVICES | ES | C | 04/05/2011 | Residential Underground: | WILSOND | WILSOND | | ES | C | 168372 | | INTERMOUNTAIN POWER SERVICES | ER | C | 04/05/2011 | | WILSOND | WILSOND | | ER | C | 168371 | | INTERMOUNTAIN POWER SERVICES | ER | T | 02/22/2011 | PAID (REC#900235) rough for kitchen not done dlw will call for kitchen rough and pay refee. (Original code: 07, desc: Elec Rough, result: PArt, inspector: DLW, Amount Due: $50.00) | WILSOND | WILSOND | | ER | T | 338 | | INTERMOUNTAIN POWER SERVICES | ER | P | 09/23/2010 | PARTIAL TO BE SEEN IN LOG COURSE...CMC (Original code: 07, desc: Elec Rough, result: part, inspector: RKD) | DRUMR | DRUMR | | ER | P | 5109 | | INTERMOUNTAIN POWER SERVICES | EUG | R | 09/23/2010 | CMC Had reduced neutral, rkd (Original code: 31, desc: Electrical Trench, result: fail, inspector: RKD) | DRUMR | DRUMR | | EUG | R | 5108 | | HOMEOWNER | H= | C | 05/04/2012 | | HARRISJ | HARRISJ | | H= | C | 176903 | | HOMEOWNER | HV | C | 04/21/2011 | bath vents and boiler vent | LANDSITTELM | LANDSITTELM | | HV | C | 168784 | | GLASER GAS, INC. | HO | C | 03/22/2011 | | LANDSITTELM | LANDSITTELM | | HO | C | 168124 | | HOMEOWNER | HI | C | 03/22/2011 | | LANDSITTELM | LANDSITTELM | | HI | C | 168122 | | GLASER GAS, INC. | HO | R | 02/17/2011 | most of trench is barely 12" deep NEEDS TO LIST GLASER OR DO NOT DO INSPECTION (Original code: 13, desc: Gas Line Yard, result: FAIL, inspector: JRH) | HARRISJ | HARRISJ | | HO | R | 400 | | LEE INDUSTRIES, LLC | OS= | C | 02/25/2011 | Rescheduled from 02/23/2011 (KNB) (Original code: 35, desc: Septic Final, result: PASS, inspector: KHD) | DAHLK | DAHLK | | OS= | C | 260 | | LEE INDUSTRIES, LLC | OS= | | 11/05/2010 | Ok to backfill. Need to inspect backfill since it may require a retaining wall. (Original code: 35, desc: Septic Final, result: HOld, inspector: KHD) | DAHLK | DAHLK | | OS= | | 2889 | | LEE INDUSTRIES, LLC | OS= | R | 11/02/2010 | Chambers too deep. Max 4' cover. Flow not evenly distributed out of d-box. Need riser at d-box and chambers bedderd.Inspection date changed per conversation with contractor. KHD CMC (Original code: 35, desc: Septic Final, result: FAIL, inspector: KHD) | DAHLK | DAHLK | | OS= | R | 3103 | | LEE INDUSTRIES, LLC | OS= | R | 09/02/2010 | cancelled. Owners not approved to install system. CALLED BY OWNER (Original code: 35, desc: Septic Final, result: , inspector: ) | | | | OS= | R | 160278 | | LEE INDUSTRIES, LLC | OSP | C | 05/14/2010 | (Original code: 33, desc: Septic Pre-Site, result: PASS, inspector: KHD) | DAHLK | DAHLK | | OSP | C | 9712 | | LEE INDUSTRIES, LLC | OSP | R | 05/11/2010 | Engineer design wrong. Called Engineer and left message on 5/12/10 (Original code: 33, desc: Septic Pre-Site, result: FAIL, inspector: KHD) | DAHLK | DAHLK | | OSP | R | 9792 | | LEE INDUSTRIES, LLC | OSP | | 05/10/2010 | Perc test received. Hold for engineer design review. (Original code: 33, desc: Septic Pre-Site, result: Hold, inspector: KHD) | DAHLK | DAHLK | | OSP | | 9829 | | LEE INDUSTRIES, LLC | OSP | R | 05/07/2010 | Inspection done. Perc test not included with application. (Original code: 33, desc: Septic Pre-Site, result: FAIL, inspector: KHD) | DAHLK | DAHLK | | OSP | R | 9839 | | HOMEOWNER | P= | C | 05/04/2012 | | HARRISJ | HARRISJ | | P= | C | 176904 | | HOMEOWNER | PTO | C | 06/07/2011 | | LANDSITTELM | LANDSITTELM | | PTO | C | 169780 | | HOMEOWNER | PTO | T | 04/21/2011 | PAID (REC#900890) DWV and water need to be on test, 3 1/2 nail guards on plates, fixture venting not to code | LANDSITTELM | LANDSITTELM | | PTO | T | 168783 | | HOMEOWNER | PB | C | 06/02/2010 | obsereved 2 trucks with Montana plates asked owner who they worked for he stated "Him" and he has workmans comp (Original code: 09, desc: Plumb Base, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | PB | C | 9372 | | HOMEOWNER | PB | R | 05/28/2010 | --drain needs sleeve thru foundation wall, layout does not appear to match plans, shower?, no horizontal dry vents, or label wet vents--CMC (Original code: 09, desc: Plumb Base, result: FAIL, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | R | 9441 |
|
|